1/4" Malleable Iron Beam Clamp, -20 Threaded Openings, Fits Flanges Up To 1-5/16" Thick, Supports Threaded Rod, Threaded Brindle Rings & Electrical Boxes, Malleable Iron With Electroplated Bright Zinc Plating, Set Screw Load Rating 250, Static Load Limit 250 LB, Based On A Safety Factor Of 3, Load Rating Based On Bottom Hole Of Beam Clamp, Torque INLB 60.
3/8", Malleable Iron Beam Clamp, -16 Threaded Openings, Fits Flanges Up To 1" Thick, Supports Threaded Rod, Threaded Brindle Rings & Electrical Boxes, Malleable Iron With Electroplated Bright Zinc Plating, Set Screw Rating 750, Static Load Limit 750 LB, Based On A Safety Factor Of 3, Load Rating Based On Bottom Hole Of Beam Clamp, Torque INLB 120.
1-1/4", 2 Piece, PVC Electrical Conduit Expansion Coupling, Designed To Compensate For Length Changes Due To Temperature Variations In Exposed Applications Of Conduit Runs, For Use With Schedule 40 & 80 Conduit, Features Exclusive Molded In Mid-Point Indicator On The Piston, Exclusive 1-1/4" Expansion Fitting With 4" Travel Distance, 2 Piece Molded Design With Lubricated Seals For Easier Movement For The Life Of The Product, 2 O-Rings To Prevent Leakage, Can Be Installed Vertically Or Horizontally.
1/2", ENT Blue Smurf Quick Connect Coupling, For Electrical Non-Metallic Tubing.
3/4", ENT Blue Smurf Quick Connect Coupling, For Electrical Non-Metallic Tubing.
1/2", ENT Blue Smurf Terminator Adapter, For Electrical Non-Metallic Tubing.
3/4", ENT Blue Smurf Terminator Adapter, For Electrical Non-Metallic Tubing.
1/2", ENT Blue Smurf Male Adapter, Threaded For Electrical Non-Metallic Tubing.
3/4", ENT Blue Smurf Male Adapter, Threaded For Electrical Non-Metallic Tubing.
1", Zinc, Water Tight Conduit Hub, Indoors Or Outdoors, Water Tight, Insulated Throat, Use To Connect Rigid Or IMC Conduit To A Load Center Or Other Metal Enclosure Where A Water Tight Joint Is Required At Knock Outs Or Slip Fit Holes, Flame Retardant Lexan Insulated Throat, Rain, Oil, & Dust Tight, Oversize Locknut Assures Vibration Proof Installation & Positive Grounding.
1-1/2", Zinc, Water Tight Conduit Hub, Indoors Or Outdoors, Water Tight, Insulated Throat, Use To Connect Rigid Or IMC Conduit To A Load Center Or Other Metal Enclosure Where A Water Tight Joint Is Required At Knock Outs Or Slip Fit Holes, Flame Retardant Lexan Insulated Throat, Rain, Oil, & Dust Tight, Oversize Locknut Assures Vibration Proof Installation & Positive Grounding.
2", Zinc, Water Tight Conduit Hub, Indoors Or Outdoors, Water Tight, Insulated Throat, Use To Connect Rigid Or IMC Conduit To A Load Center Or Other Metal Enclosure Where A Water Tight Joint Is Required At Knock Outs Or Slip Fit Holes, Flame Retardant Lexan Insulated Throat, Rain, Oil, & Dust Tight, Oversize Locknut Assures Vibration Proof Installation & Positive Grounding.
2 Pack, 1/2", Non-Metallic Snaptite Connector, Indoors Only, Snap In, Fits Non-Metallic Cable #14/2, #12/2, #12/3, Awg Or 2 #14/2 Awg Or Flex Cord .300 To .560" Diameter 3/8", 1/2' Knock Out, In A Dry Location, Use To Connect Non-Metallic Sheathed Cable To A Steel Outlet Box Or Other Metal Enclosure, 3/8" Size Fits 1/2" Knock Out , Snap In Design Allows For Quick & Easy Installation, No Locknut Required.
2 Pack, 3/4", Non-Metallic Snaptite Connector, Indoors Only, Snap In, Fits Non-Metallic Cable #14/2, #12/2, #12/3, Awg Or 2 #14/2 Awg Or Flex Cord .300 To .560" Diameter 3/8", 1/2 Knock Out, In A Dry Location, Use To Connect Non-Metallic Sheathed Cable To A Steel Outlet Box Or Other Metal Enclosure, 3/8" Size Fits 1/2" Knock Out , Snap In Design Allows For Quick & Easy Installation, No Locknut Required.